(((ELKRON))) - MP110
2.5 Outputs
2.5.1 Output programming table
BURGLARY
YES
YES
YES
TAMPER
YES
YES
YES
PANIC
NO
YES
YES
TECHNOLOGICAL
NO
YES
YES
FIRE
YES
YES
YES
CHIME/GONG
NO
YES
YES
FAILURE
NO
YES
YES
LPA
NO
YES
YES
TC1
NO
YES
YES
TC2
NO
YES
YES
TC3
NO
YES
YES
OR TC
NO
YES
YES
AND TC
NO
YES
YES
RESET FIRE DET.
NO
YES
YES
BUZZER
NO
YES
NO
SYSTEM STATUS
NO
YES
NO
NH/NL
YES
YES
YES
NPN/PNP
NO
YES
NO
U1 - CONTROL UNIT
U2, U3, U4, U5
CONTROL UNIT
U2, U3, U4, U5
ESP.
NPN OUTPUT
PNP OUTPUT
+
+
negative
command
+
positive
command
TC1, TC2, TC3 OR
TC1, TC2. TC3 AND
Voltage at the
output is +12V if
at least one of the
TC’s is present
(+12V)
Voltage at the output
is +12V only if all
TC’s are present
(+12V)
15