4.5
System activation/
deactivation by electronic key
Commutator leds 1 (zone 1), 3 (zone 2) and 4 (zone 3) indicate the
system’s current status:
ON = armed zones
OFF = disarmed zones
1. Insert the commutator key and leave it inserted.
2. If the key inserted controls only one of the three zones, the status of
the zone for which the key operation is enabled changes immediately.
3. If the key controls more than one zone, the system cyclically indicates
the possible combinations that can be applied for a maximum of 4
times. If the key controls two zones, the system displays the following
sequence:
If the key controls all three zones, the system offers the following
sequence:
Removal of the key with one of these combinations set causes
permanent arming of the selected mode and triggers the exit delay
procedure (when programmed). With the key permanently inserted, at
the end of the fourth cycle, the system exits the procedure and remains
in the previous mode.
4. To disarm the system, insert the key and remove it when the leds go
OFF.
ON =
ZONE 1 ARMED
OFF =
ZONE 1 DISARMED
ON =
ZONE 2 ARMED
OFF =
ZONE 2 DISARMED
ON =
ZONE 3 ARMED
OFF =
ZONE 3 DISARMED
1
1
ON
-
3
ON
removal of key arms both zones
2
1
ON
-
3 OFF
removal of key arms zone 1
3
1 OFF -
3
ON
removal of key arms zone 2
1
1
ON
3
ON
4
ON
removal of key arms all three zones
2
1
ON
3 OFF
4 OFF
removal of key arms zone 1
3
1 OFF
3
ON
4 OFF
removal of key arms zone 2
4
1
ON
3
ON
4 OFF
removal of key arms zones 1 and 2
5
1 OFF
3 OFF
4 ON
removal of key arms zone 3
6
1
ON
3 OFF
4
ON
removal of key arms zones 1 and 3
7
1 OFF
3
ON
4
ON
removal of key arms zones 2 and 3