(((ELKRON))) - MP110
4.3 Enabling/Disabling of
User Codes 5, 6, 7 and 8
1. Enter MASTER code.
2. Press key
EXIT
F
and then press key
C
**
twice.The LCD display will
show the message: “CODE AUX 05”. The segment display will show
number 5 (user 5 code). To choose another code to enable/disable,
press keys
1
or
2
: the display will show the chosen code.
3. By means of leds 1,2,3 the sectors controlled by the code under
reference are visualized.
Led on= sector controlled by the code under reference.
Led off= sector not controlled by the code under reference.
If, for example, all 3 leds are on, it means that the user under reference
can arm or disarm the whole plant; if on the contrary only led 1 is on,
it means that the user can manage sector 1 only.
If all 3 leds are off, the code under reference is disabled.
4. To modify the visualized association press key
C
**
.
(The leds of the associated sectors flash) and by keys
1
,
2
,
3
(corresponding to sectors S1,S2,S3) , associate or not the
desired sectors to the user under reference.
The indication of the associated sector is provided by the flashing of
the corresponding led. If the led is off, it means that the corresponding
sector is not operating (for the code under reference).
5. At the end of the configuration of the code under reference, press key
C
**
. The leds of the associated sectors will turn on in a fixed mode.
6. To modify the association of the sectors of another code, choose it by
keys
1
or
2
,then proceed as described from point 3 onwards.
7. Press key
EXIT
F
twice to exit and to store the choices made.
1
2
3
associate zone 1
associate zone 2
associate zone 3
3
2
1 3
zone 1
zone 2
zone 3
40