5.14 Direct Display of Failures
The keypad buzzer is immediately activated in the presence of a failure event, and the cause of the failure
is displayed on the display. All the failure type programmed outputs are also activated. The displaying of
failure events on both the LCD and LED are of maximum priority. Consequently, such indications will cover
(conceal) any default messages (e.g., date and time).
If there is a concurrence of failures, all the causes will be repeatedly displayed in rotation. Failure
messages will disappear only if the causes that triggered them are eliminated. The same is true for the
buzzer warning.The buzzer may be turned off, even during a failure, by pressing the ‘F’ key.
The following table contains all the possible messages that can be displayed on the two different keypads.
The characters on keypads with led display are displayed with flashing.
LCD DISPLAY
LED
CAUSE
UNIT F1
FF
F1 unit fuse failure (Inputs)
UNIT F2
FF
F2 unit fuse failure (Outputs)
UNIT F3
FF
F3 unit fuse failure (Peripheries serial)
EXPANSION FUSE 1
FF
Expansion fuse 1 failure
EXPANSION FUSE 2
FF
Expansion fuse 2 failure
EXPANSION FUSE 3
FF
Expansion fuse 3 failure
EXPANSION FUSE 4
FF
Expansion fuse 4 failure
NO UNIT NETWORK
AL
Absence of unit network
NO EXPANS.NETWORK 1 AL
Absence of expansion 1 network
NO EXPANS.NETWORK 2 AL
Absence of expansion 2 network
NO EXPANS.NETWORK 3 AL
Absence of expansion 3 network
NO EXPANS.NETWORK 4 AL
Absence of expansion 4 network
BATTERY LOW
bL
Battery run-down or missing
UNIT SENS.POWER SUP
PF
Low power supply in unit sensor
EXP1 SENS.POWER SUP. PF
Low power supply in expansion 1 sensors
EXP2 SENS.POWER SUP. PF
Low power supply in expansion 2 sensors
EXP3 SENS.POWER SUP. PF
Low power supply in expansion 3 sensors
EXP4 SENS.POWER SUP. PF
Low power supply in expansion 4 sensors
EXP 1 AUX ZONE
1A
1A zone alarm if programmed as failure
EXP 2 AUX ZONE
2A
2A zone alarm if programmed as failure
EXP 3 AUX ZONE
3A
3A zone alarm if programmed as failure
EXP 4 AUX ZONE
4A
4A zone alarm if programmed as failure
MANAGEMENT OF NETWORK ABSENCE/RESTORATION
The system provides for 5 network control points. One in the unit (intrinsic), and another for each expansion When the
auxiliary input is programmed for control, the absence of network on one or more control points is indicated as a failure,
and recorded in the event log, only at the end of the 1 hour timeout. The same holds true for the restoration of network,
when there is a 1/2 hour timeout. The network is considered to be present only if present at all control points.
The event is displayed clearly on the LCD display, and the message disappears as soon as soon as the cause that
triggered has been eliminated.