(((ELKRON))) - MP110
3.1
Factory parameters
To take the CONTROL UNIT back to factory parameters the following procedure must be carried out:
1. Deactivate CONTROL UNIT (OFF)
2. Position in ON dip switch n.1 (DEF)
3. Shortcircuit for a moment PIN-STRIP RST contacts and wait for a double confirmation BIP from buzzer.
4. Take back to OFF dip switch n.1
1
5
2
6
3
7
4
8
ON
ON
D
E
F
C
O
C
1
N
U
IT
0
IT
1
N
U
2
4
H
O
F
F
WARNING !
1. The following programmings are not lost when the unit is restored to factory parameters:
- programming of telephone numbers and their type (voice, numerical and remote-control
management)
- association of event to telephone number the key code and its association
-
the key code and its association
- date/hour
2. Once the factory parameters have been rest, the CONTROL UNIT automatically goes to ON (Total
activation). To deactivate it is sufficient to enter a valid code . User factory code: 1-11111
3.1.1 Factory parameters: access codes
3.0 SYSTEM RUNNING
ON
N°
name
Code
Associated sectors Enabling
1
MASTER code
111111
1-2-3
YES
2
USER 2
2 22222
1-2-3
NO
3
INSTALLER
3 33333
1-2-3
YES
4
SURVEILLANCE
4 44444
-
NO
5
USER 5
5 55555
-
NO
6
USER 6
6 66666
-
NO
7
USER 7
7 77777
-
NO
8
USER 8
8 88888
-
NO
22