(((ELKRON))) - MP110
TECHNICAL CHARACTERISTICS OF UNITS MP110 – MP110M – MP110TG
AND OF PS515 - PS28 (Meanwell S-40-15) POWER SUPPLY
- Rated power supply voltage
230V~ 50Hz +10 -15% (MP110M metallic version with PS28)
230V~ 50Hz +10 -15% (plastic versions with PS515)
- Max current absorption
250mA (vers. with PS515), 500 mA (vers. with PS28)
- Unit board absorption at 12V
50mA at rest with balanced inputs
70 mA with inputs NC
- Max board absorption during alarm
65mA, at rest with balanced inputs
85 mA with inputs NC
- Unit operating voltage
10V5 to 15V-
- Rated voltage at PS515/PS28 power supply output
13,8V- adjustable
- Max current supplied by the PS515 unit
1.5A
-
Max current supplied by the
PS28
unit
2,8A
- Max ripple PS515
300mV p.p. with I = 1.5A
- Max ripple PS28
100mV p.p. with I = 2,8A
- Measured efficiency
approx. 86%
- Current available for ext. devices
200 mA for versions MP110 to MP110TG
(keypads, sensors, horns)
550 mA for version MP110M
- Accumulator placed in plastic cont.
12V to 6.5Ah (Max 7Ah), versions MP110 to MP110TG
- Accumulator placed in metal cont.
12V to 15Ah (max 17 Ah ), version MP110M
- Anti-tamper
1A - 24V -
- Declared operating temperature
-10°C to +55°C
- Certified CEI standard operating temp.
+5°C to +40°C
- Guaranteed performance level
I (with positive lines Not Connected)
II (with balanced or double balanced lines)
- Max length of unit-peripheral serialline
500 meters*(2x0.75 cable sect.for 2 x 0.22 x data)
- Max current supplied at electrical auxiliary indication outputs
(TC, panic,fire)
10mA
- Min/Max input time
0 sec to 90 sec at steps of10
- Output time
same as input time + 10 sec
- Relay alarm time
programmable between 30 s and 9 min
- Indication of optical (LCD) and electrical failure due to low unit battery, fuses, low expansion board supply
- Programmable output failure alarm time as long as failure lasts
- Run-down battery threshold adjustment
11.2 V to 11.4 V ± 5%
- Battery Test: automatic (only PS515)
every hour and at switching to ON/OFF
- Degree of protection provided by casing
IP30/ IK 02
TECHNICAL CHARACTERISTICS OF REMOTE KEYPADS KP100 - KP100D LINKED TO MP110 SYSTEM
- Rated power supply voltage
12V-(drawn from motherboard - serial line)
- Min/Max operating voltage
10V5 to 15V-
- Rated 12V input current(vers. KP100)
18mA (all sectors OFF;21mA all sectors ON;
48mA (all sectors ON + retro lighting; max 70 mA during test)
- Rated 12V input current(vers. KP100D)
21mA (all sectors OFF;31mA all sectors ON;
90mA (all sectors ON + retro lighting;max 105mA duringtest)
- Type of communication
Elkron serial protocol
- Max length of serial line from unit
500 meters* (2x0.75 cable sect. for 2 x 0.22 x data)
- Max number of connectable keypads
4
- Series anti-tamper/anti-removal with clear indication addressed on unit
- Degree of protection provided by casing
IP30 / IK 02
- Max number of possible combinations
100.000