(((ELKRON))) - MP110
5.3
Inputs/Sectors
Association
•
It is possible to associate one input to one or more sectors. An input
associated to no sector becomes unused even if the opening of this
input is anyway signalled by
led.
1. Enter installer code
2. Press twice key
EXIT
F
+ key
6
: input 1 programming is
visualized.
3. By keys
1
2
.select the input to be associated. The sectors
associated to the input under reference are visualized by corresponding
S1,S2,S3 leds going on. Led on =Sector associated.
4. To access the modification of selected input, press key
6
.
The leds of associated sectors flash quickly. To modify association,
use the corresponding sector keys
1
2
3
. By
pressing key
TOTAL
the status of the three sectors will be
complemented.
5. Press
6
to confirm selection made.
6. By pressing
EXIT
F
, you leave the procedure and save the selections
made. Leaving by timeout the modifications made are not considered.
LED keyboard shows the number of
the input under reference, while LCD
keyboard shows the message "AS-
SOCIATE ZONE:xx" where "xx"
means the input under reference.
Led on fixed
= Sector associated
PROCEDURE ACCESS
INST.
CODE
EXIT
F
EXIT
F
6
3
2
1 3
S1
S2
S3
5.4
Output programming and
association to sector
•
This procedure allows to program the outputs to the management of one
of the possible alarm events. It also allows to specify the NH/NL level
(normally high/normally low) of the electric outputs, the association to
the sectors, and the AND/OR sectors mode for Burglary and TC
outputs.
•
Output 01 (control unit relay) is exclusively dedicated to the manage-
ment of the burglary alarm and it is also possible to give it the
management of the tamper alarm (with system OFF) and FIRE alarm.
It is associated to the 3 sectors in OR sectors mode and this
configuration cannot be modified.
•
Output 01 (control unit relay) always manages the tamper alarm with
system ON ( even only 1 armed sector).
•
For all other electric outputs, one of the possible modes can be
selected.
PROCEDURE ACCESS
INST.
CODE
EXIT
F
EXIT
F
4
The segment keypad visualizes the
number of the output under refer-
ence, while the LCD keypad visual-
izes the message “PRG OUT xx
ttttt”, where “xx” corresponds to the
output under reference and “ttttt” cor-
responds to the programmed mode.
50