PROCEDURES ACCESSIBLE TO MASTER CODE AND INSTALLER CODE
3.4.1
Active input Exclusion
1. Enter MASTER or INSTALLER code. Press
E
.
2. The first input available for exclusion is proposed with message
"INSULATION Z. nn" for LCD display (nn=zone number to be excluded).
LED keyboard shows only the input number in a fixed way.
3. By key
1
the desired input is selected forward
By key
2
the desired input is selected backward
By key
TOTAL
you go back to the list beginning
4.
Press
E
to exclude the zone under consideration.
The message “ZONE nn INSULAT” is displayed on the LCD keypad.
The number of the zone flashes on the LED keypad display. If all
zones are EXCLUDED, the message “ALL Z INSULATED” appears
on the LCD display.
The LED display will indicate “__”
5.
Press
EXIT
F
to exit the programming function.
3.4.2
Excluded
input inclusion
1. Enter MASTER or INSTALLER code. Press
O
2. Re-entry of the first EXCLUDED zone is indicated with the message
“SETTING ZONE nn” on the LCD display (nn=zone number). The LED
keypad display indicates only the zone number with a fixed light.
3. Use the
1
key to select the other EXCLUDED zones by scrolling
the list forward. Press the
2
key to select zones by scrolling the
list backward. Press the
TOTAL
key to return to top of list.
4. To include the input under reference, press
O
5. LCD keyboard shows the message "ZONE nn SETTED" LED keyboard
shows the zone number in a flashing way. To select the following input,
press key
1
or
2
If there is no excluded input:
LCD display shows message “ALL ZONES SETTED ”
LED display shows the message: “—”
3.4
Visualization input status
NOTE:
In order to keep inputs under
observance without generating
any alarm , after completing the
installation, it is possible to
exclude all inputs from alarms.
TO BE NOTED that an
excluded input is active on all
foreseen functions (Open
Input,Memorizations, Alarm
Count, Prealarm,etc.) except
for the activation of the alarm
output to serve the alarm and
to send the event to the
communicator.
30