(((ELKRON))) - MP110
PROGRAMMABILITY
CONTROL UNIT
EXPANSIONS READERS KEYBOARD
PHYSICAL CONNECTION MODE
NORMALLY CLOSED
YES
YES
YES
YES
SINGLE BALANCING
YES
YES
NO
NO
DOUBLE BALANCING
YES
YES
NO
NO
INPUTS ACTIVE 24H
PANIC WITH SIREN
YES
YES
YES
SILENT PANIC
YES
YES
YES
YES
FIRE
YES
YES
YES
YES
TECHNOLOGICAL
YES
YES
YES
YES
BURGLARY INPUT ASSIGN.
INSTANT
YES
YES
YES
YES
DELAYED
YES
YES
YES
YES
LAST OUTPUT
YES
YES
YES
YES
CHIME GONG
YES
YES
YES
YES
• INSTANT inputs (NC to positive or Balanced. to positive)
If open, they generate immediate alarm if the relevant sector is activated.
• DELAYED inputs (NC to positive or Balanced to positive)
If they are opened
during
the output delay they generate no alarm. If
they stay open or are opened
after
the output delay, the input time will
be activated, after which if the system is not placed in OFF, alarm will
be generated.
• LAST OUTPUT Inputs
The opening and the subsequent closing of one LAST OUTPUT input
during the output delay puts this time at about 5s.
2.4.2 Burglary inputs programming
EXAMPLE OF USE OF LAST OUTPUT
INPUTS WITH DELAYED PATH
CM
= microcontact (last output input)
IR
= infrared (delayed input)
KP
= remote keyboard
IIR is connected to a delayed input, CM to a programmed
LAST OUTPUT input. By activating the station from KP IR
measure is not considered, the following CM opening and
re-closing takes output delay to 5 seconds. If an intruder
gets in from a window there will be an immediate alarm
(even if IR is delayed). If he gets in from the door protected
by CM the entrance delay will be enabled.
window
2.4.1 Input programming table
12