5.10 Masking Programming
•
The MASKING programming allows to mask the system status to non
authorized people (the operation details are described in para 4.5.1).
1. Enter installer code.
2.
Press twice key
EXIT
F
+ key
8
to access procedure.
Leds visualize the current status (see side ):
3. Press key
8
to change programming status.
4. By pressing key
EXIT
F
you leave programing and assume the selected
status, Leaving by timeout, the previously memorized status is kept.
5.11 Alarms count, commutating
lock with open zones, open
zone self-bypassing
•
For burglary events it is possible to program a max.number of alarms
(0 to 9) that can be generated by every input, then the following openings
of the burglary inputs that have already reached the count are only
stored in the event log without generating any alarm.
•
The opening of an input during an alarm is not considered for counting
purposes.
•
During the WALK-TEST the ring count is considered.
•
At the end of this count, the display will show the relevant open input
without activating the buzzer.
•
The counter is reset every time that the control unit goes ON/OFF or
every 24 h if this manoeuvre does not take place.
•
In this programming it is also possible to enable/disable the commutat-
ing lock with open zones and the open zone self-bypassing.
•
This last operation can be enabled only if the commutating lock with
open zones has been previously enabled.
-
COMMUTATING LOCK WITH OPEN ZONES: if the commutating
lock with open zones has been programmed, it will not be possible to
arm –neither from keypad nor by DK key – the sectors to which the
currently open zones are associated. If you try such an arming from
keypad, a relevant warning is provided on the display and no arming will
take place.
-
OPEN ZONE SELF-BYPASSING: If both commutating lock and
self-bypassing have been programmed, the zones left open are
automatically bypassed when an arming from keypad or DK key is
carried out.
PROCEDURE ACCESS
INST.
CODE
EXIT
F
EXIT
F
O
NOTE
If the commutating lock is
programmed with associated
open zone self-bypassing, the
arming is however not allowed
if open 24h inputs are present.
55