(((ELKRON))) - MP110
2.3
Terminal Board
Description
1/2
LA/LB
Telephone line input
3/4
PA/PB
Telephone line output
5
Earth terminal for the
connection of the screen
6
-
Negative of supply
7
+
Positive of supply
8
C
Battery test (Only PS515)
9
-BAT
Battery negative
10
+BAT
Battery positive
11
-SIR
Negative of siren supply
12
+SIR
Positive of siren supply
13
C
14
NO
Relay output 1, max capacity 1 A 24Vdc
15
NC
16
U2
Open Collector electric output 2 (I max 10mA)
17
U3
Open Collector electric output 3 (I max 10mA)
18
U4
Open Collector electric output 4 (I max 10mA)
19
U5
Open Collector electric output 5 (I max 10mA)
20
-SER
Devices supply on serial line
21
+SER
Devices supply on serial line
22
CK
Serial line (synchronism)
23
D
Serial line (data)
24
-S
Negative of detector supply
25
+S
Positive of detector supply
26
Z1
Zone 1: programmable input
27
Z2
Zone 2: programmable input
28
Z3
Zone 3: programmable input
29
Z4
Zone 4: programmable input
30
Z5
Zone 5: programmable input
31
Z6
Zone 6: programmable input
32
Z7
Zone 7: programmable input
33
Z8
Zone 8: programmable input
34
-S
Negative of detector supply
35
+S
Positive of detector supply
36
TA
24h Input
37
KEY
Mechanical key input
The type (NPN/PNP) of electrical
outputs U2,U3,U4,U5 can be
programmed through links.
Leaving the links as they are from the
factory (see figure above) electric
output is normally high (+12V) at rest
(PNP) and is lost in case of alarm. The
opposite setting makes output become
NPN,i.e. normally low (0V) at rest,
which is lost in case of alarm.
OUTPUT LEVEL
PROGRAMMING
U2
U3 U4 U5
10
F3-F1A-250V
F1-F1A-250V