Doc
#
E149701
B-60
B: Modbus Map and Retrieving Logs
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
[0C 04 1E 4B 10 24]1 [01 C0]2 [01 C0]3 [00]4 [00]5 [00 00]6 [00
00]7
[00 00]8 [00 00]9 [00 00]10 [00 00]11 [00 00]12 [00 00]13 [00 00]14
[00 00]15
[D3 21]16 [19 6C]17 [1C B0]18 [02 64]19 [D3 AA]20 [1A F3]21 [00 00 00
00
00 00 00 00 00 00 00 00 00 00]22 [00 00 00 00 00 00]23
From the above content, the values would be as follows:
timestamp= 2012/04/30 11:16:36 AM
present_states = 0000 0001 1100 0000 (
see table above for bit breakdown
)
Volts C Sag
Volts B Sag
Volts A Sag
event_channels = 0000 0001 1100 0000 (
see table above for bit breakdown
)
Volts C Sag
Volts B Sag
Volts A Sag
7
Va surge
19
Ib calibration
8
Vb surge
20
Vc calibration
9
Vc surge
21
Ic calibration
10
Ia surge
22
not used
11
Ib surge
23
padded zeroes
12
Ic surge
-
-
PQ Event Record Binary Content Mapping
Superscript #
Content
Superscript #
Content
Summary of Contents for Shark 200