43
Full-electronic HV-Tester F1-1x Typs
6. INTERFACES
6.1.2 X6
Warning lamp set 94-2C connection
The round connector is for the connection of the Elabo warning lamp set
94-2C.
X6-1
Phase (230 V) for green lamp
X6-2
Phase (230 V) for red lamp
X6-3
N for both lamps
X6-4
Spare
PE