C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 553 –
◆
Link Trace Cache Hold Time
– The hold time for CFM link trace cache
entries. (Range: 1-65535 minutes; Default: 100 minutes)
Before setting the aging time for cache entries, the cache must first be
enabled in the Linktrace Cache attribute field.
◆
Link Trace Cache Size
– The maximum size for the link trace cache.
(Range: 1-4095 entries; Default: 100 entries)
If the cache reaches the maximum number of specified entries, or the
size is set to a value less than the current number of stored entries, no
new entries are added. To add additional entries, the cache size must
first be increased, or purged (see
"Displaying Fault Notification
Continuity Check Errors
◆
Connectivity Check Config
– Sends a trap if this device receives a
continuity check message (CCM) with the same maintenance end point
identifier (MPID) as its own but with a different source MAC address,
indicating that a CFM configuration error exists.
◆
Connectivity Check Loop
– Sends a trap if this device receives a CCM
with the same source MAC address and MPID as its own, indicating that
a forwarding loop exists.
◆
Connectivity Check MEP Down
– Sends a trap if this device loses
connectivity with a remote maintenance end point (MEP), or
connectivity has been restored to a remote MEP which has recovered
from an error condition.
◆
Connectivity Check MEP Up
– Sends a trap if a remote MEP is
discovered and added to the local database, the port state of a
previously discovered remote MEP changes, or a CCM is received from a
remote MEP which as an expired entry in the archived database.
MEP Up traps are suppressed when cross-checking of MEPs is enabled
9
because cross-check traps include more detailed status information.
Cross-check Errors
◆
Cross Check MA Up
– Sends a trap when all remote MEPs in an MA
come up.
An MA Up trap is sent if cross-checking is enabled
, and a CCM is
received from all remote MEPs configured in the static list for this
maintenance association
10
.
◆
Cross Check MEP Missing
– Sends a trap if the cross-check timer
expires and no CCMs have been received from a remote MEP configured
in the static list.
A MEP Missing trap is sent if cross-checking is enabled
, and no CCM is
received for a remote MEP configured in the static list
9. Cross-checking must be enabled for this type of trap to be reported (see
).
10. See
Summary of Contents for ECS4660-28F
Page 1: ...Management Guide www edge core com ECS4660 28F Layer 3 Gigabit Ethernet Switch...
Page 2: ......
Page 4: ......
Page 12: ...ABOUT THIS GUIDE 12...
Page 64: ...CONTENTS 64...
Page 90: ...TABLES 90...
Page 92: ...SECTION I Getting Started 92...
Page 122: ...SECTION II Web Configuration 122 Multicast Routing on page 825...
Page 148: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 148...
Page 224: ...CHAPTER 5 Interface Configuration VLAN Trunking 224 Figure 68 Configuring VLAN Trunking...
Page 262: ...CHAPTER 6 VLAN Configuration Configuring VLAN Translation 262...
Page 304: ...CHAPTER 9 Congestion Control Automatic Traffic Control 304...
Page 340: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 340...
Page 452: ...CHAPTER 13 Security Measures DHCP Snooping 452...
Page 740: ...CHAPTER 17 IP Services Configuring the PPPoE Intermediate Agent 740...
Page 866: ...CHAPTER 21 Multicast Routing Configuring PIMv6 for IPv6 866...
Page 882: ...CHAPTER 22 Using the Command Line Interface CLI Command Groups 882...
Page 1024: ...CHAPTER 26 Remote Monitoring Commands 1024...
Page 1030: ...CHAPTER 27 Flow Sampling Commands 1030...
Page 1088: ...CHAPTER 28 Authentication Commands PPPoE Intermediate Agent 1088...
Page 1162: ...CHAPTER 29 General Security Measures Configuring Port based Traffic Segmentation 1162...
Page 1186: ...CHAPTER 30 Access Control Lists ACL Information 1186...
Page 1214: ...CHAPTER 31 Interface Commands Transceiver Threshold Configuration 1214...
Page 1238: ...CHAPTER 33 Port Mirroring Commands RSPAN Mirroring Commands 1238...
Page 1258: ...CHAPTER 34 Congestion Control Commands Automatic Traffic Control Commands 1258...
Page 1270: ...CHAPTER 36 UniDirectional Link Detection Commands 1270...
Page 1276: ...CHAPTER 37 Address Table Commands 1276...
Page 1336: ...CHAPTER 39 ERPS Commands 1336...
Page 1386: ...CHAPTER 40 VLAN Commands Configuring Voice VLANs 1386...
Page 1406: ...CHAPTER 41 Class of Service Commands Priority Commands Layer 3 and 4 1406...
Page 1424: ...CHAPTER 42 Quality of Service Commands 1424...
Page 1536: ...CHAPTER 43 Multicast Filtering Commands MLD Proxy Routing 1536...
Page 1602: ...CHAPTER 45 CFM Commands Delay Measure Operations 1602...
Page 1624: ...CHAPTER 47 Domain Name Service Commands 1624...
Page 1646: ...CHAPTER 48 DHCP Commands DHCP Server 1646...
Page 1974: ...SECTION IV Appendices 1974...
Page 1980: ...APPENDIX A Software Specifications Management Information Bases 1980...