16
Step 1
– Remove the screws connecting the
transformers
PRIMARY
wires to
the terminal strip with a flat blade
screwdriver (3mm).
Step 3
– Using a soldering iron & a
solder sucker remove the wires
connecting the transformer to the
Triacs. Mark the wires to allow for
easier reconnection.
IMPORTANT NOTE: Power MUST be switched off before removing transformer.
Disassembly
Step 2
– Remove the clear tubing covering
the blue wire & using a soldering
iron & a solder sucker disconnect
the blue & brown wires connecting
the transformer & the PCB.
Step 4
– Remove the screws holding the
transformer in place using a Phillips
head screwdriver (two point).
Replacing the
Transformer –
ESC 36 - 48 220V
BLUE
BROWN
Summary of Contents for ESC 16
Page 3: ...Installation and Operating Instructions ESC 16 ESC 24 ESC 36 ESC 48 FOR MODELS TM...
Page 24: ...22 Notes...
Page 25: ......
Page 26: ...P N 401633 2 TM...
Page 27: ...ECO matic ESC Chlorinator SERVICING INSTRUCTIONS ESC SERVICE GUIDE...
Page 52: ...26 Troubleshooting Guides...
Page 53: ...27...
Page 54: ...28...
Page 55: ...29...
Page 56: ...30...
Page 64: ...38 NOTES...
Page 65: ...39...
Page 68: ...ESC SERIES SALT CHLORINATOR...
Page 69: ...EcoSalt BMSC Chlorinator SERVICING INSTRUCTIONS ECOSALT SERVICE GUIDE...
Page 89: ...21 Trouble Shooting Guides...
Page 90: ...22...
Page 91: ...23...
Page 92: ...24...
Page 97: ...EcoSpa ORP Controlled Sanitising System SERVICING INSTRUCTIONS ECOSPA SERVICE GUIDE...
Page 109: ...13 Step 4 Place cable ties into position holding the fuse wires in place...
Page 112: ...16 Trouble Shooting Guides...
Page 113: ...17...
Page 114: ...18...
Page 115: ...19...
Page 116: ...20...
Page 117: ...21 This page intentionally blank...
Page 118: ...22 NOTES...
Page 119: ...23 NOTES...