6
Indicators – What They Mean
Output readings on the DIGITAL DISPLAY can fall due to any (or combination of) the following: cooler water
temperatures, warming of power pack (in heated equipment rooms for example), lower than normal power voltage, low
salt levels, scaling occurring on ‘Cell’.
Provided LED 1 and LED 2 are both GREEN ( and the ‘Cell’ is not scaling excessively), your ECO-matic is performing
(producing) satisfactorily.
Indicator
Display
LED 1 LED 2 What’s Happening
STAND-BY ON
Blank
Green Green 1. Unit is in start-up mode.
2. ‘Cell’ is in OFF cycle during normal operation.
(refer
System Control
)
3.
System Control
set at MIN.
FLOW ON
Blank
Green Green 1. Insufficient flow through ‘Cell’ (gas or air at STAND-BY ON
‘Cell’, check pump/pipes for damage, leaks).
2. Gas Sensor lead not connected to ‘Cell’.
3. System is wired incorrectly.
Approx 90-100
Green Green System operating normally.
Approx 90-100
Green Red
1. ‘Cell’ is dirty, scale build-up. Clean ‘Cell’.
2. Water temperature cold. Switch to
Winter Mode
.
3. Salt Level below minimum. Add salt.
4. ‘Cell’ failing. Test and/or replace ‘Cell’.
Varying
Red
Red
Unit preparing to
Cut-Out
. (see
Low Salinity Indicator
and
Cut-Out
)
1. ‘Cell’ is dirty, scale build-up. Clean ‘Cell’.
2. Water temperature cold. Switch to
Winter Mode
.
3. Salt Level below minimum. Add salt.
4. ‘Cell’ failing. Test and/or replace ‘Cell’.
STAND-BY ON
Blank
Red
Red
System Protection activated. Unit has
Cut-Out
.
Follow above procedures
WINTER MODE ON Approx 75-85 Green Green System operating normally - in
Winter Mode
.
Only operate in
Winter Mode
if water is very cold.
Red LED(s): Scaled ‘Cell’ or Low Salt Level.
Operation of the ESC Models
The ESC Models have the following features:
a)
Polarity Indicator
: The + or - symbol appears before the
Digital Output Display
, to indicate the polarity in which
the system is operating (i.e. positive or negative direction of ‘Cell’ current). The symbol will alternate according to
pre-set factory settings and does not effect the normal operation of the unit.
b)
System Control
: When the
System Control
is being adjusted, the ESC units will indicate (flashing) the percentage
of time that the ‘Cell’ will operate during the filtration cycle (for a few seconds, then display reverts to ‘Cell’ Output
display).
c)
‘Cell’ Cleaning
: The ESC units use a patented Electronic Auto-Cleaning system for the ‘Cell’. ‘Cells’ may eventually
scale in extreme hard water conditions and will require manual cleaning if this occurs.
d) The second
Low Salinity
warning phase (Red + Red LED’s) is very short. Therefore on first warning phase (Red +
Green LED’s) prompt action is recommended to avoid
Cut-Out
.
Summary of Contents for ESC 16
Page 3: ...Installation and Operating Instructions ESC 16 ESC 24 ESC 36 ESC 48 FOR MODELS TM...
Page 24: ...22 Notes...
Page 25: ......
Page 26: ...P N 401633 2 TM...
Page 27: ...ECO matic ESC Chlorinator SERVICING INSTRUCTIONS ESC SERVICE GUIDE...
Page 52: ...26 Troubleshooting Guides...
Page 53: ...27...
Page 54: ...28...
Page 55: ...29...
Page 56: ...30...
Page 64: ...38 NOTES...
Page 65: ...39...
Page 68: ...ESC SERIES SALT CHLORINATOR...
Page 69: ...EcoSalt BMSC Chlorinator SERVICING INSTRUCTIONS ECOSALT SERVICE GUIDE...
Page 89: ...21 Trouble Shooting Guides...
Page 90: ...22...
Page 91: ...23...
Page 92: ...24...
Page 97: ...EcoSpa ORP Controlled Sanitising System SERVICING INSTRUCTIONS ECOSPA SERVICE GUIDE...
Page 109: ...13 Step 4 Place cable ties into position holding the fuse wires in place...
Page 112: ...16 Trouble Shooting Guides...
Page 113: ...17...
Page 114: ...18...
Page 115: ...19...
Page 116: ...20...
Page 117: ...21 This page intentionally blank...
Page 118: ...22 NOTES...
Page 119: ...23 NOTES...