8 Parameter list
8.4 Parameter groups for RASP5
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
185
8.4.4 Parameter group 3 (Mechanical brake and digital inputs)
Table 43:
Parameter group 3 (Mechanical brake and digital inputs)
Parameter
Designation
Description
Unit
Min
Max
DS
P3-01
Brake mode
Control of the mechanical brake
0: Simple mode (P3-02, P3-03)
1: extended mode (P3-02 to P3-05)
–
0
1
0
P3-02
Brake f-open
Frequency limit at which the external brake is opened.
Condition: RUN (start enable)
Hz/rpm
0
P1-01
1.5
P3-03
Brake f-close
Frequency limit at which the external brake is closed.
Hz/rpm
0
P1-01
1
P3-04
Brake M-Level
Release
Required motor torque level at which the brake may be
released.
Determines the torque in % of the rated motor torque, which
has to be present before the mechanical brake may be
released. It is used to ensure that the motor is connected and
produces sufficient torque to prevent the load dropping on
release of the mechanical brake.
This function is not active in V/f mode (P6-01 = 6)
A
0
P1-07
0
P3-05
Brake release delay
Determines the time before the mechanical brake is
released.
s
0
320
0
P3-06
SEN I1 Logic
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
–
0
1
0
P3-07
SEN I2 Logic
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
–
0
1
0
P3-08
SEN I3 Logic
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
–
0
1
0
P3-09
SENI4 Logic
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
–
0
1
0
P3-11
t-dec Select B0
Selection deceleration ramp bit 0
External stop function
0: deactivated
1: activated
–
0
1
0