6 RASP5 speed controller
6.4 Specific technical data
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
139
DC braking
I/I
e
%
≦
100, adjustable
≦
100, adjustable
≦
100, adjustable
≦
100, adjustable
Rated voltage for brake control
U
V AC
RASP5-xx1… (180 V DC)
RASP5-xx2… (230/277 V AC)
RASP5-xx4… (400/480 V AC)
Switching frequency
f
PWM
kHz
8 (adjustable 4–32)
V/f characteristic
Linear
Linear
Linear
Linear
Heat dissipation at rated current
(I
e
) and switching frequency
(f
PWM
) of 6 kHz
P
v
W
32
46
58
95
Heat dissipation at idle
(standby) with AS-Interface
supply voltage
P
v
W
< 9
< 9
< 9
< 12
Efficiency
η
0.97
0.98
0.98
0.98
Fan
internal
temperature controlled
Device fans on heat sink
–
–
–
Fan
Output frequency
f
z
Hz
50/60 Hz, adjustable 0 - 320 Hz
1. Fixed frequency (P1-12)
f
z
Hz
30
30
30
30
2. Fixed frequency (P2-01)
f
z
Hz
40
40
40
40
3. Fixed frequency (P2-02)
f
z
Hz
50
50
50
50
4. Fixed frequency (P2-03)
f
z
Hz
50
50
50
50
Response time with default settings
Motor On (automatic)
1)
t
ON
ms
< 10
< 10
< 10
< 10
Motor Off (automatic)
1)
t
OFF
ms
< 10
< 10
< 10
< 10
Motor Off (quick stop)
t
OFF
ms
< 10
< 10
< 10
< 10
Minimum pulse duration I3/I4
t
ON
ms
5
5
5
5
longest permissible length of
motor cable
(EMC, 2nd environment, C3)
l
m
25
25
25
25
Weight
(Without/with repair switch)
m
kg
3.4/3.7
3.4/3.7
3.4/3.7
3.4/3.8
1) without bus runtime, depending on PLC.
Symbol
Unit
RASP5-2…
RASP5-4…
RASP5-5…
RASP5-8…