Maintenance
4-59
7
1
2
3
4
5
REPLACING THE FAN PLATE
AVAILABILITY
• No mission capable
OPERATOR(S)
• 1 operator
TIME REQUIRED
• 5 minutes
REMOVAL
• Unscrew the two captive screws (see Plate 6.III, item 4) securing the fan plate (item 3).
• Disconnect the fan cable from the connector on cable W3 from the synchronisation
board (see Plate 6.VIII).
• Extract the fan plate (item 3)
INSTALLATION
• Present the fan plate (item 3) by passing the cable in the rack.
• Connect the fan cable to the connector on cable W3 from the synchronisation board
(see Plate 6.VIII).
• Secure the fan plate with the two captive screws (item 4).
COMPLEMENTARY OPERATION(S)
• Test the IDR IDO 3G (see Sheet P-2).
SHEET
E-7