Maintenance
This d
t and its contents are the property of CASSIDIAN
nd must not be copied or circul
7
1
2
3
4
5
• For the transmission cables (W30, W31a or W31b), disable transmission
(see Section 3.4.4).
• For the mains power cables (W0 and W1), set the primary convertor's “I/O” switch
(see Plate 6.IV, item 2 or 9) to “O”.
• Disconnect the cable at each end, referring to the replacement sheets of the
interconnected sub-assemblies concerned.
• Remove the cable.
INSTALLATION
• Connect the cable at each end, referring to the replacement sheets of the
interconnected sub-assemblies concerned. Use the appropriate torque wrenches for the
SMA and N connectors.
• Attach the cables together as they were originally, using the cable ties.
• For the transmission cables (W30, W31a or W31b), enable transmission.
• For the mains power cables (W0 and W1), set the primary convertor's “I/O” switch
(see Plate 6.IV, item 2 or 9) to “I”.
COMPLEMENTARY OPERATION(S)
• After replacing an internal rack cable, replace the upper cover (see Plate 6.I, item 1).
• Test the IDR IDO 3G (see Sheet P-2).
SHEET E-1