Maintenance
4-57
7
1
2
3
4
5
REPLACING AN DUPLEXER
AVAILABILITY
• No mission capable
OPERATOR(S)
• 1 operator
TIME REQUIRED
• 5 minutes
TOOL(S)
• 1 standard tool box
• 1 torque wrench for tightening the N connector, torque 500 N.cm
PRELIMINARY OPERATION(S)
• Remove the clear protective cover (see Plate 6.I, item 13) by slightly unscrewing the
holding screws, lifting it and taking it out.
SHEET
E-6