4-52
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
69
set serial
port baud
rate
This
command
is for AE
Bus only. It
can not be
used with
PROFIBUS
and
Ethernet
interfaces.
Sets the serial port baud rate.
Send three data bytes
• Byte 1 is only for compatibility and is
ignored.
• Bytes 2 and 3 set the baud rate (send
least significant byte first). Valid baud
rates are:
4
9600
4
19200
4
38400
4
57600
4
115200
Note:
For 115200, the selection value is 0
Read back with command
212
.
3
1
(CSR only)
93
set pulsing
frequency
Sets the RF pulsing frequency.
Send three data bytes, least significant
byte first, representing the pulsing
frequency in Hertz.
• Accepts a value of 1 to 100000 (1 Hz
to 100000 Hz).
Note:
Ensure the value does not exceed
the specified maximum pulse
frequency of the generator (see
“Electrical Specifications” on
page 3-9
).
See also commands
27
and
96
. For more
information, see
Read back with command
193
.
3
1
(CSR only)
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...