HPG 13150 400 V (A)
Communication Interfaces
4-65
HPG™ 13150 400 V RF Power Generator
Prerelease version
212
report serial
port 0
address
and baud
rate
This
command
is for AE
Bus only. It
can not be
used with
PROFIBUS
and
Ethernet
interfaces.
Returns the serial port address and baud
rate.
The controller returns three data bytes:
• Byte 1 is always address 1
• Bytes 2 and 3 = baud rate
4
9600
4
19200
4
38400
4
57600
4
115200
Note:
For 115200, the return value is 0
Set with command
69
.
0
3
223
report error
code
register
Retrieves the error code. See also
“Checking for and Resolving Errors and
Warnings” on page 6-6
0
1
230
report
sensor data
Returns sensor data:
• Bytes 0 and 1 = Reserved
• Bytes 2 and 3 = Condensation
0
4
231
report unit
serial
number
The controller returns four data bytes
representing the serial number (LSB first)
0
4
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...