E35 Filament Current
Too High
Filament current is above upper limit.
).
E40 Maximum Tube
Power Exceeded
Tube power exceeded limit.
Causes:
• Plate voltage multiplied by plate current exceeded the
maximum input power of the tube.
•
Cooling water is too conductive.
Solutions:
• Reduce VSWR.
• Reduce output power.
•
Make sure that cooling water is within specifications
(see
“Cooling Specifications” on page 3-10
E41 Maximum Plate
Current Exceeded
Plate current exceeded limit.
Causes:
• The plate current exceeded the maximum current of
the tube.
•
Cooling water is too conductive.
Solutions:
• Reduce VSWR.
• Reduce output power.
• Make sure that cooling water is within specifications
(see
“Cooling Specifications” on page 3-10
• Increase the plate voltage by changing the mains
transformer tap settings.
Note:
Changing the taps is a technical procedure that
can only be done by properly trained
personnel. For more information, see the HPG
generator service manual.
E42 Maximum Grid
Current Exceeded
Grid current exceeded limit.
Cause: Combination of VSWR and output power exceeds
generator limits.
Solutions:
• Reduce VSWR at given output power.
• Reduce output power at given VSWR.
Table 6-1. Error description and resolution (Continued)
Error Message
Description and Resolution
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...