HPG 13150 400 V (A)
Troubleshooting and Customer Support
6-9
HPG™ 13150 400 V RF Power Generator
Prerelease version
E12 HV Supply
Temperature Too High
HV transformer temperature is too high.
Cause: Ambient temperature too high/air flow too low.
Solution:
1. Check to see that the air flow is unobstructed and
below the specified input temperature (see
).
2. Listen to ensure that the fans are operating properly.
E20 Chill Plate Humidity
Too High
Driver power section (chill plate) humidity is too high (only
where humidity sensor is available).
• HV is switched off.
• HPG will reinitialize after error condition has gone.
Cause: Humidity sensor on chill plate reports too high
humidity.
Solution:
1. Switch off generator and disconnect the mains.
The
ON/OFF
power switch does not completely
disconnect the
Mains
. You must have an external switch
installed to completely disconnect the
Mains
.
2. Turn off the water source.
3. Check the water connections for leaks.
4. Check water temperature (low water temperature
causes condensation).
5. Dry any condensation in the generator before
reconnecting mains.
Table 6-1. Error description and resolution (Continued)
Error Message
Description and Resolution
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...