HPG 13150 400 V (A)
Communication Interfaces
4-37
HPG™ 13150 400 V RF Power Generator
Prerelease version
6
Unit ID
0 (denotes the default AE Bus address)
7
Function code
23 = 0x17h
8 and 9
Reference
number for
read
0xFFFFh
Note:
This value is necessary to denote
the special use of FC23 (mapping
to AE Bus commands).
10 and 11
Word count
Not used
12 and 13
Reference
number for
write
0xFFFFh
Note:
This value is necessary to denote
the special use of FC23 (mapping
to AE Bus commands).
14 and 15
Word count for
write
Not used
16
Byte count for
write
Not used
17
AE Bus
command
number
AE Bus command number; see
complete list of commands
18
Number of
bytes in AE
Bus write
packet
Total number of bytes in the AE Bus
packet; for a description of the AE Bus
packet, see
; for information on the number
of data bytes in
each AE Bus command,
see
19 and up
AE Bus data
bytes
Data bytes contained in the AE Bus
packet; for a description of the data bytes
for each command, see
Note:
Modbus word swapping does not
affect the order of these bytes.
These bytes should be ordered as
necessary for the AE Bus
command (least significant bytes
first).
Table 4-9. Packet format for FC23 send (Continued)
Byte
Numbers
Purpose
Value to Send
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...