HPG 13150 400 V (A)
Installation, Setup, and Operation
5-39
HPG™ 13150 400 V RF Power Generator
Prerelease version
2. Power ramping recipe
The function mode allows you to determine the shape of a power ramp
within a certain time frame. There are four programmable time frames.
For each time frame, you may control the following parameters:
•
Set the time duration of the presence of RF power from 0.1 second
to 1440 minutes
•
Set the start value of the RF power in watts
•
Set the end value of the RF power in watts
Creating Recipes Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
HPG generator:
Note:
For host port commands, see
1. Set the number of recipes:
Send one data byte for command
19
, representing the desired number of
recipe steps.
2. Specify the ramp time for each given recipe using command
21
:
a. Send one byte to select the step number 1 to 2
b. Send two bytes to set the ramp time value.
3. Specify the set point for each given recipe step using command
22
:
a. Send one byte to select the recipe step number 1 to 2
b. Send two bytes to specify the set point value.
4. Set the run time for each given recipe using command
23
:
a. Send one byte to select the recipe step number 1 to 2.
b. Send two bytes to set the run time in seconds.
5. Set the ramping rise time:
Send two bytes, least significant byte first, for command
31
, representing
the ramping rise time in tenths of a second.
6. Set the ramping fall time:
a. Send two bytes, least significant byte first, for command
32
,
representing the ramping fall time in tenths of a second.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...