HPG 13150 400 V (A)
Communication Interfaces
4-47
HPG™ 13150 400 V RF Power Generator
Prerelease version
18
Profibus
version
RF
frequency
(see
previous
row for AE
Bus/
Ethernet
version of
command)
Sets the RF frequency.
Send three data bytes representing the
RF frequency in 100 Hertz steps (for
example, 10000 = 1 MHz).
Note:
This command is only available on
generators with variable frequency.
Read back with command
178
.
3
1
(CSR only)
19
number of
recipe
steps
Specifies the number of recipe steps.
Send one data byte, representing the
desired number of recipe steps
• Accepts a value of 0 through 2.
Note:
0 disables recipe settings.
For more information, see
1
1
(CSR only)
21
recipe step/
ramp time
Specifies the ramp time for a given recipe
step.
Send three data bytes, least significant
byte first:
• Byte 1 selects the recipe step
number (1 to 2) (set with command
19
).
• Bytes 2 and 3 set the ramp time
value in tenths of a second. Send a
value from 0 to 36000 (one hour).
For more information, see
Read back with command
191
.
3
1
(CSR only)
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...