4-62
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
169
report
forward
power limit
Reports programmed limit for forward
power.
The controller returns the user forward
power limit in watts.
Set with command
4
.
0
2
170
report
reflected
power limit
Reports reflected power limit.
The controller returns two data bytes
representing the value in watts.
Set with command
5
.
0
2
175
report
capacitor
positions
Reports current load and series motor
positions.
The controller returns four data bytes,
least significant byte first.
• Bytes 1 and 2 report the current load
position (0 to 1000)
• Bytes 3 and 4 report the current
series position (0 to 1000).
Set with commands
112
and
122
or by
using the automatic tune process.
0
4
177
report
pulsing
Reports pulsing settings. The controller
returns one data byte.
• 0 = Pulsing off
• 1 = Internal pulsing
• 2 = External pulsing
• 3 = External pulsing inverted
• 4 = Enable internal pulsing by
external pulsing input
Set with command
27
.
0
1
178
report RF
frequency
Reports RF frequency in Hertz.
Note:
This command is only available on
generators with variable frequency.
Set with command
18
.
0
4
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...