HPG 13150 400 V (A)
Installation, Setup, and Operation
5-3
HPG™ 13150 400 V RF Power Generator
Prerelease version
INSTALLING THE HPG GENERATOR
The following sections explain how to install the unit.
Grounding
The HPG generator is grounded through the mains connection. For more
information on making that connection, see
Connecting Cooling Water
The
Water In
and
Water Out
connectors are 1/2" fittings (1/2" BSP thread) on
the back panel of the HPG generator (see
). On
customer request, these connectors may be equipped with quick release
couplings. The HPG generator water cooling system includes a water
solenoid, water flow meter, and a humidity sensor, which are designed to
protect the generator and the environment.
To Connect Cooling Water:
1. Install a source of water to the
Water In
connector.
2. Install a source of water out to the
Water Out
connector.
Never integrate the HPG generator into a cabinet in a way that may either
reduce or interrupt a proper airstream.
If you connect the cooling water on multiple units in series, be sure that
input water temperature to all units is less than the maximum input water
temperature (see
“Cooling Specifications” on page 3-10
).
Do not use de-ionized water for cooling purposes. De-ionized water
causes both corrosion and erosion of cooling manifolds.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...