4-38
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
FC23 Response Packet
describes the bytes contained in an FC23 response packet.
Table 4-10. Packet format for FC23 response
Byte
Numbers
Purpose
Response Value
0 and 1
Transaction ID
Not used (value is copied from send
packet)
2 and 3
Protocol ID
0
4 and 5
Number of
bytes following
Count of bytes in packet, starting with
byte 6
6
Unit ID
0 (copied from send packet; denotes the
default AE Bus address)
7
Function code
23 = 0x17h
8
Byte counter
Not used
9
AE Bus
command
number
AE Bus command number; see
for a complete list of
commands
10
Number of
bytes in AE
Bus response
packet
Total number of bytes in the AE Bus
packet; for a description of the AE Bus
packet, see
; for information on the number
of data bytes in each AE Bus command,
see
11 and up
AE Bus data
bytes
Data bytes contained in the AE Bus
packet; for a description of the data bytes
for each command, see
Note:
Modbus word swapping does not
affect the order of these bytes.
These bytes are ordered as
necessary for the AE Bus
command (least significant bytes
first).
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...