4-8
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
4
17
RF POWER ON
Digital
input
This signal enables or
disables RF output. To enable
RF output, apply a positive
voltage of 4 V to 30 V to this
pin. To disable RF output,
apply a voltage of 1.5 V or
less to this pin.
For a wiring diagram, see
.
Note:
Before the HPG
generator can deliver
power, the interlock
must be satisfied (see
“Satisfying Minimal 25-
Pin User Port
Requirements” on
page 4-4
) and the set
point must be within the
output power range
(see
Pin 17 must be grounded.
Table 4-2. 25-pin User Port pin descriptions (Continued)
Pin
Number
Return
Pin
Name
Signal
Type
Description
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...