ELECTRICAL SPECIFICATIONS
describes the electrical specifications of the HPG generator.
Table 3-2. Electrical specifications
Description
Specification
Input power specifications
Line voltage
400 VAC ± 10% (factory setting)
440 VAC ± 10%
480 VAC ± 10%
(selected by user changing the transformer taps)
Note:
Changing the taps is a technical procedure
that can only be done by properly trained
personnel. For more information on
changing the taps, see the HPG generator
service manual.
Source frequency
46-63 Hz, 3-phase
Line current
46 A each
φ
at 400 VAC nominal
42 A at 440 VAC
38A at 480 VAC
(selected by user changing the transformer taps)
Input power
32 kVA at 15 kW RF power
Power factor
90% at maximum RF power level
Overcurrent protection
80 A to 100 A adjustable circuit breaker
Efficiency (line to load)
53%, typical at full-rated power, nominal line%,
typical at full-rated power, nominal line, into a 50
Ω
load
RF output specifications
Frequency
13.56 MHz ±0.005%
Minimum output power
150 W into a 50
Ω
nonreactive load
Note:
The HPG generator can operate below this
level, but accuracy is not guaranteed.
Maximum output power
15 kW into a 50
Ω
nonreactive load
Delivered power into
mismatch
15 kW into a 1.1:1 VSWR
13.75 kW into a 1.2:1 VSWR
12 kW into a 2.0:1 VSWR
10 kW into a 3.0:1 VSWR
Maximum reflected
power
1.5 kW into an infinite VSWR
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...