HPG 13150 400 V (A)
Installation, Setup, and Operation
5-31
HPG™ 13150 400 V RF Power Generator
Prerelease version
6. Press
Reset
to reset the lifetime counter.
7. Press
Ok
when the reset message appears.
8. Press
Ok
.
9. Press the
Exit
soft key.
10. Press the
Execute
soft key.
REFLECTED POWER SETTINGS
The HPG generator can tolerate continuous reflected power; however, it
allows you to set a value at which the forward power will fold back when the
reflected power reaches a certain limit for a specified period of time. The
Reflected Power Settings
menu allows you to create a
reaction profile
to
shut off RF power when the reflected power reaches this limit.
To Set a Reflected Power Reaction Profile Using the HPG Generator Front Panel:
1. Press the
Program
soft key.
2. Press
Next
until you see
Reflected Power Settings
on the display.
3. Press
Change
.
4. Set a
Prefl. Threshold
between 20 W and 200 W using the
RF POWER
rotary knob.
5. Press
Ok
.
6. If you want the generator to shut off when it reaches this limit for a
specified period of time, press
On
. Otherwise, press
Off
.
a. If you select
On
:
4
Set the desired
max refl.
value (between 12 W and 180 W) using the
RF POWER
rotary dial knob.
4
Set the desired
RF Off After
value (between 1 µs and 3 m 20 s) using
the
RF POWER
rotary dial knob.
4
Press
Ok
to confirm.
7. Press the
Exit
soft key.
8. Press the
Execute
soft key.
READING AND SETTING TUBE LIFETIME PARAMETERS
The tube lifetime menu options allow you to read tube lifetime parameters and
to enable the tube lifetime counter. These menu options also allow authorized
personnel to reset the tube lifetime counter when the tube is replaced. (This
function requires a passcode and will only be performed by authorized
Dressler personnel.)
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...