5-28
Installation, Setup, and Operation
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
The
Recipe Settings
operating screen displays the actual position on the
ramp by a moving cursor point, in addition to the start and total running time.
If RF power is turned off during the
Recipe Settings
function, by hand, or
error, then the time stops. You may then:
•
Press
Quit
to stop.
•
Press
Restart
to start from the beginning.
•
Press
Continue
last
val
to continue at the same position you stopped at
before.
To Turn Off the Recipe Settings Feature Using the HPG Generator Front Panel:
1. Press the
Program
soft key.
2. Press
Next
until you see
Recipe Settings
on the display.
3. Press
Change
.
4. Press
Off
to turn off the feature.
5. Press the
Exit
soft key.
6. Press the
Execute
soft key.
For 8 minutes, a linear increasing power level from 150 W to 895 W.
For 6 minutes and 10 seconds, a linear increasing power level from 755 W to 1160 W.
For 7 minutes and 18 seconds, a linear decreasing power from 1160 W to 0 W.
For 22 minutes and 40 seconds, a linear decreasing power level from 895 W to 755 W.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...