Warning Descriptions and Resolutions
Warning conditions do not shut output power off, and the warning message is
cleared when the condition that caused the warning condition is gone. The
front panel only displays one warning message at a time. Overload warnings
indicate that an operating limit has been exceeded, and the unit has reduced
output power to remain within the allowable range.
When an overload warning
is active, the unit is not meeting set point.
On the front panel, overload
messages end with an exclamation point.
lists the warning messages that may occur on the HPG generator,
describes each warning message, and explains how to resolve the associated
problem.
Table 6-2. Warning description and resolution
Warning Message
Description and Resolution
W10
DC power at limit!
The driver power has exceeded the limit. The unit has
reduced output to remain within the limits.
Output is not at
set point.
Cause: VSWR is too high.
Solution: Reduce VSWR.
W11
Pforw. maximum
reached!
This warning occurs in load power regulation mode when
the forward power required to reach the load power set
point exceeds the maximum forward power. The unit has
reduced forward power output to remain within the limits.
Output is not at set point.
Cause: VSWR is too high.
Solution: Reduce VSWR.
W12
Prefl. at limit!
The reflected power has exceeded the maximum level.
The unit has reduced forward power output to remain
within the limits.
Output is not at set point.
Cause: VSWR is too high.
Solution: Reduce VSWR.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...