6-6
Troubleshooting and Customer Support
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
Checking for and Resolving Errors and Warnings
The HPG generator responds to many error and warning conditions. Errors
and warnings display on the front panel (errors appear in E
XX
form and
warnings in W
XX
form, followed by the message text). Errors are also
reported through command 223 on the
Host
port. (See
)
Note:
This revision of the manual provides information associated with
software release 1.16. This version of the software included changes to
the error and warning messages. Please use an appropriate revision of
this manual for earlier versions of the software. If you do not have the
appropriate manual, contact Customer Support (see
). The unit reports the software revision level with
host port command
198
).
Error conditions always turn output off. If multiple error conditions exist, the
unit displays all errors. When operating in front panel control mode, you need
to reset the unit after the condition that caused the error has been resolved.
Once the condition is resolved, the front panel displays a
Quit
soft key, which
you press to reset the unit. The
Quit
soft key will not display until the error
condition is resolved. (In remote control mode, the unit automatically resets
after the condition that caused the error is resolved.)
Warning conditions do not shut output power off, and the warning message is
cleared when the condition that caused the warning condition is gone. The
front panel only displays one warning message at a time. Overload warnings
indicate that an operating limit has been exceeded, and the unit has reduced
output power to remain within the allowable range.
When an overload warning
is active, the unit is not meeting set point.
On the front panel, overload
messages end with an exclamation point.
The following sections describe error and warning messages, describe their
causes, and explain how to resolve them.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...