background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC345A-R2 

UMA1089 Rev C 

 

 

VGA/HDTV Scaler Plus 

 

Scales video, converts and transforms formats 

 

Summary of Contents for AC345A-R2

Page 1: ...AC345A R2 UMA1089 Rev C VGA HDTV Scaler Plus Scales video converts and transforms formats ...

Page 2: ... Support at 724 746 5500 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 20 seconds TRADEMARKS USED IN THIS MANUAL BLACK BOX and its logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 3: ... the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the eq...

Page 4: ...mpidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Pr...

Page 5: ... 6 2 OVERVIEW 7 2 1 INTRODUCTION 7 2 2 FEATURES 7 2 3 WHAT S INCLUDED 8 2 4 HARDWARE DESCRIPTION 8 3 INSTALLATION 9 3 1 CONNECTIONS 9 3 2 CONNECTION BLOCK DIAGRAM 9 4 CONFIGURATION OPERATION 10 4 1 INPUT AND OUTPUT 10 4 2 MENUS AND ADJUSTMENTS 10 5 TROUBLESHOOTING 13 5 1 CONTACTING BLACK BOX 13 5 2 SHIPPING AND PACKAGING 13 ...

Page 6: ...5 1 Specifications 1 1 General Connectors Input 1 HD15 Output 2 HD15 1 processed and 1 bypassed Operating Temperature 32 to 122 F 0 to 50 C Power 5 VDC 2 6 A CE FCC UL certified Dimensions 1 H x 4 W x 6 5 D 2 5 x 10 2 x 16 5 cm Weight 0 75 lb 0 34 kg ...

Page 7: ...40x900 WXGA 60 Hz 1440x900 WXGA 60 Hz 1280x1024 SXGA 60 75 85 Hz 1280x1024 SXGA 60 Hz 1400x1050 SXGA 60 Hz 1400x1050 SXGA 60 Hz 1600x1200 UXGA 60 Hz 1600x1200 UXGA 60 Hz 1680x1050 WSXGA 60 Hz 1680x1050 WSXGA 60 Hz 1920x1080 60 Hz 1920x1080 60 Hz 1920x1200 WUXGA 60 Hz 1920x1200 WUXGA 60 Hz 480I 60 Hz 480I 60 Hz 480P 60 Hz 480P 60 Hz 576I 50 Hz 576I 50 Hz 576P 50 Hz 576P 50 Hz 720P50 50 Hz 720P50 50...

Page 8: ...r The VGA HDTV Scaler Plus also includes a horizontal mirroring feature that you can use for teleprompter s and rear projection systems The VGA HDTV Scaler Plus features an OSD menu for configuration picture setup system information and many other advanced options 2 2 Features Any PC or HDTV video signal can be scaled up or scaled down to any other PC or HDTV resolution Adjustable output frame rat...

Page 9: ...d 2 4 Hardware Description 2 4 1 Front Panel Figure 2 1 shows side 1 panel of the VGA HDTV Video Scaler Plus Table 2 1 describes its components TABLE 2 1 Component Description HD15 Connector Output Bypass HD15 Connector PC HD Input 2 4 2 Back Panel Figure 2 2 shows side 2 panel of the VGA HDTV Video Scaler Plus Table 2 2 describes its components TABLE 2 2 Component Description Barrel Connector 5 V...

Page 10: ...he HD15 to YPbPr 3 RCA cable to convert YPbPr for HDTV devices The scaler includes a display local loop out connection labeled Bypass Output Use this connection to send a non processed signal to a secondary display 3 2 Connection Block Diagram Figure 3 2 DVD Connection Processed Output Bypassed Output Figure 3 1 PC Connection Processed Output Processed Output ...

Page 11: ...UNE For RGB Video Input PHASE refers to nanosecond timing position of each sample taken This adjustment can be used to align the pixels grabbed by the SC VGA 2B to those created by the video source Range is 0 100 default 73 CLOCK changes the number of samples per display line The unit samples the video at the nominal pixel rate For example a 1024x768 resolution signal is sampled 1024 times during ...

Page 12: ...YPbPr BLUE Adjust BLUE RGB value Range is 0 100 default 47 RGB or 48 YPbPr EXIT Exit COLOR Submenu SIZE Select this option to toggle between FULL PANSCAN LETTERBOX UNDERSCAN or OVERSCAN display modes The change occurs as each option is selected Default FULL SOURCE AUTO Automatically detects the type of input video source based on the selected resolution Default PC Forces the input video source to ...

Page 13: ...t 90 TIMER Select the approximate number of seconds for the OSD to be displayed on the screen before turning off Range 0 100 default 10 BACKGROUND Changes opacity of the OSD background on the screen 0 is a black background 100 is a transparent background Range 0 100 default 10 EXIT Exit OSD Submenu FACTORY RESET Select this option to reset all values to the factory defaults INFORMATION Displays so...

Page 14: ...ble on the VGA HDTV Scaler Plus output but setting the unit to output YPbPr resolutions 480p for example Use supplied HD15 to 3 RCA to make sure that only the desired YPbPr sync signals are sent to the display device 5 1 Contacting Black Box If you determine that your Receiver is malfunctioning do not attempt to repair the unit Contact Black Box Tech Support at 724 746 5500 or info blackbox com Be...

Page 15: ...724 746 5500 blackbox com VGA HDTV Scaler Plus 14 ...

Page 16: ...8 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2010 All rights reserved Great tech support is just 20 seconds away at 724 746 5500 or blackbox com ...