47
STEP 16A - INSTALLING THE SWITCH ON THE STANDARD F41 MODEL
Secure the pump switch (item 1) to the cab control box (item 2) (alarm side) with two 1/4” x 5/8” lg self-threading
screws (item 3). Adjust the switch control at the same angle as the box controls. Connect the wire (item 4) to the
wire on the pump motor and from the wire (item 5), connect the white wire (item 6) to the white wire of the main feed
and connect the black wire (item 7) to the ground terminal.
ALARM
VOLUME
SPOUT
COURBURE
DEFLECTEUR
DEFLECTOR
LUMIERE
LIGHT
DECROCHAGE
UNHOOK
FEEDROLL
TRANSMISSION
SPOUT
COURBURE
DEFLECTEUR
DEFLECTOR
LUMIERE
LIGHT
DECROCHAGE
UNHOOK
FEEDROLL
TRANSMISSION
1
3
4
2
7
6
5
ALARM
MAIN TERMINAL
(+)
MAIN
POWER
Towards
Forage
Harvester
black
EMERGENCY
white
white (+)
Figure 44
STEP 16B - INSTALLING THE SWITCH ON THE STINGER F41 MODEL
Install the switch (item 1) to the left or right of the control box (item 2) by replacing the bracket by the extra bracket
supplied with the kit (item 3). Use the bolts already in place. Connect the wire (item 4) to the wire on the pump motor
and from the wire (item 5), connect the white wire (item 6) to the white wire of the main power supply and connect
the black wire (item 7) to the ground terminal. To do so, first loosen the cable clamp, insert the power cable, make
the connection then put it back in place.
3
7
6
2
1
1
5
4
Figure 45
ASSEMBLING INSTRUCTIONS - LIQUID INCORPORATION SYSTEM
At the edge
of plate
Manual
No
. F4117E987E V1.1