38
ASSEMBLING INSTRUCTIONS
INSTALLING THE INSPECTION LIGHT - FIGURE 26
When the inspection light (OPTION) must be installed,
proceed as follows:
NOTE:
Skip items 1 to 4 if the spout deflector light is
already installed or in the case of a F41 Stinger
model.
Quick disconnect the power cable (item 20) from
the control box before making the connections.
1. Open the control box (item 1) located in the tractor
cab. Install the toggle switch (item 2) and fix it prop-
erly making sure, using an oheter, that current goes
through when the toggle switch is «ON» as shown
on the control box decal.
2. Use the wires (item 3) located on the side of the
alarm. Connect the white-yellow wire (item 4) on the
terminal (item 5) of the toggle switch.
3. Connect the supplied wire (item 6) on the other
switch terminal (item 7) and on the box terminal
(item 8).
4. Close up the box and leave the toggle switch to
«OFF».
5. Connect the plug (item 9) of the wire (item 10) of the
inspection light (item 11) with already mounted wire
(item 17). If the Forage Harvester is equipped with
the spout light, use the supplied ”Y”-shape plugs
(item 12).
6. Bring the wire along the side of the spout and secure
it with nylon tie-wraps.
7. Bring the wire and run it through the slotted hole
(item 13) facing the quick-disconnect hitch.
8. Install the female plug (item 14) as shown. Use two
8-32 x 3/4” lg bolts (item 15), two lock washers and
two hexagonal nuts
9. Connect the inspection light (item 11) to the female
plug (item 14). The inspection light is equipped with
a magnet support (item 16) that allows the operator
to fix it anywhere for handy maintenance. When not
in used, the inspection light should be put back in
the tool box.
7
6
5
4
2
20
8
3
1
ALARM
MAIN POWER
EMERGENCY
STOP
white (+)
MAIN TERMINAL (+)
Figure 26 Inspection light
Manual
No
. F4117E987E V1.1