TESTING THE OVERLOAD LIMIT SWITCHES
-
the second safety limit switch (RK5) backs up
if the first switch outreach limit switch (RK4)
fails
-
disable the RK4 for testing by disconnecting the
conductor 40 and connecting the conductors 13
and 39 in the chassis control panel with a
jumper lead
-
retract and extend the boom and measure the length of the
telescope extension´s protruding part
The measure must be 2,350 mm ±50 mm.
-
if the protruding part is too long, adjust the limit switches and
secure their position with a seal
-
ATTENTION! Remember to resume the operation of the
RK4 by connecting the conductor to terminal 40 and
removing the jumper lead.
Summary of Contents for DINO 260XT
Page 2: ...DINO 260XT 2...
Page 3: ...DINO 260XT 3 OPERATING INSTRUCTIONS Valid from serial number 26121...
Page 6: ...DINO 260XT 6 REACH DIAGRAM...
Page 12: ...DINO 260XT 12...
Page 14: ...DINO 260XT 14 28L 28 28R 13 14 12 15 6 16 1 5 32 2 29 3 31 4A 10 34 7 33 8 9 11 4B...
Page 16: ...DINO 260XT 16 30A 26 25 23 20 36 18 22 30B 35 24 19 17 21...
Page 22: ...DINO 260XT 22 28L 28 28R 13 14 12 15 6 16 1 5 32 2 29 3 31 4A 10 34 7 33 8 9 11 4B...
Page 24: ...DINO 260XT 24 24 30A 26 25 23 20 36 18 19 22 17 21 30B 35...
Page 40: ...DINO 260XT 40 LUBRICATION PLAN...
Page 42: ...DINO 260XT 42 1...
Page 81: ...DINO 260XT 81...
Page 82: ...DINO 260XT 82 ELECTRIC DIAGRAM 26094...
Page 83: ...DINO 260XT 83...
Page 84: ...DINO 260XT 84...
Page 85: ...DINO 260XT 85...
Page 86: ...DINO 260XT 86...
Page 87: ...DINO 260XT 87...
Page 88: ...DINO 260XT 88...
Page 89: ...DINO 260XT 89...
Page 90: ...DINO 260XT 90...
Page 91: ...DINO 260XT 91...
Page 92: ...DINO 260XT 92...
Page 93: ...DINO 260XT 93...
Page 94: ...DINO 260XT 94...
Page 95: ...DINO 260XT 95...
Page 96: ...DINO 260XT 96...
Page 97: ......
Page 99: ...DINO 260XT 99 HYDRAULIC DIAGRAM BOOM SYSTEM 26102...
Page 100: ...DINO 260XT 100...
Page 101: ...DINO 260XT 101 Notes...