LEVELLING SYSTEM OF THE PLATFORM
-
A so-called Slave Cylinder System is applied for levelling of the platform:
-
the slave cylinder under the platform is controlled by a master cylinder
-
the platform keeps its level position only if the valves in the system are tight
-
the levelling system comprises the following parts:
36
Master cylinder
37. Slave cylinder
23. Load regulation valve
20
Double load regulation valve
12. Electric directional valve
-
If the platform, viewed by the operator, drifts forwards, the reason can be:
1.
a leak in the slave cylinder double load regulation valve (on the piston rod side) in the direction of the
electric directional valve (which is not tight)
2.
an internal leakage in the cylinder
-
If the platform, viewed by the operator, drifts backwards, the reason can be:
1.
a leak in the load regulation valve (20) on the piston (bottom) side of the slave cylinder in the
direction of the electric directional valve (12) (which is not tight)
2.
an internal leakage in the cylinder
The leak will cause drifting of the platform until the load regulation valve (23) under the platform id
closed. The closing is caused by dropping of the pressure on the piston rod side to the opening ratio,
which is 5:1
Air in the levelling system causes inaccuracy during levelling of the platform.
If the valves are not tight, refer to the service instructions in the chapter "load holding and load regulation
valves"
Settings of the load regulation valves:
-
the opening pressure of the double load regulation valves (20) is 25 MPa (250 bar)
-
the opening pressure of the load regulation valve (23) under the platform is 21.5 MPa (215 bar)
Do not change the preset values.
Summary of Contents for DINO 260XT
Page 2: ...DINO 260XT 2...
Page 3: ...DINO 260XT 3 OPERATING INSTRUCTIONS Valid from serial number 26121...
Page 6: ...DINO 260XT 6 REACH DIAGRAM...
Page 12: ...DINO 260XT 12...
Page 14: ...DINO 260XT 14 28L 28 28R 13 14 12 15 6 16 1 5 32 2 29 3 31 4A 10 34 7 33 8 9 11 4B...
Page 16: ...DINO 260XT 16 30A 26 25 23 20 36 18 22 30B 35 24 19 17 21...
Page 22: ...DINO 260XT 22 28L 28 28R 13 14 12 15 6 16 1 5 32 2 29 3 31 4A 10 34 7 33 8 9 11 4B...
Page 24: ...DINO 260XT 24 24 30A 26 25 23 20 36 18 19 22 17 21 30B 35...
Page 40: ...DINO 260XT 40 LUBRICATION PLAN...
Page 42: ...DINO 260XT 42 1...
Page 81: ...DINO 260XT 81...
Page 82: ...DINO 260XT 82 ELECTRIC DIAGRAM 26094...
Page 83: ...DINO 260XT 83...
Page 84: ...DINO 260XT 84...
Page 85: ...DINO 260XT 85...
Page 86: ...DINO 260XT 86...
Page 87: ...DINO 260XT 87...
Page 88: ...DINO 260XT 88...
Page 89: ...DINO 260XT 89...
Page 90: ...DINO 260XT 90...
Page 91: ...DINO 260XT 91...
Page 92: ...DINO 260XT 92...
Page 93: ...DINO 260XT 93...
Page 94: ...DINO 260XT 94...
Page 95: ...DINO 260XT 95...
Page 96: ...DINO 260XT 96...
Page 97: ......
Page 99: ...DINO 260XT 99 HYDRAULIC DIAGRAM BOOM SYSTEM 26102...
Page 100: ...DINO 260XT 100...
Page 101: ...DINO 260XT 101 Notes...