Settings:
This parameter is used to set the speed gain switching rate when the gain switching
condition is satisfied. Please refer to P2-27 for gain switching control selection
settings and refer to P2-29 for gain switching condition settings.
P2-06
KVI
Speed Integral Compensation
Address: 020CH
020DH
Operation
Interface:
Keypad/Software
Communication
Related Section:
Section 6.3.6
Default:
100
Control
Mode:
ALL
Unit: rad/s
Range: 0 ~ 1023
Data Size: 16-bit
Display
Format:
Decimal
Settings:
This parameter is used to set the integral time of speed loop. When the value of speed
integral compensation is increased, it can improve the speed response ability and
decrease the speed control deviation. However, if the setting value is over high, it may
generate vibration or noise.
P2-07
KVF Speed Feed Forward Gain
Address: 020EH
020FH
Operation
Interface:
Keypad/Software
Communication
Related Section:
Section 6.3.6
Default:
0
Control
Mode:
ALL
Unit: %
Range: 0 ~ 100
Data Size: 16-bit
Display
Format:
Decimal
Settings:
This parameter is used to set the feed forward gain when executing speed control
command.
When using speed smooth command, increase gain can improve speed track
deviation.
When not using speed smooth command, decrease gain can improve the resonance
condition of mechanical system.
P2-08
■
PCTL Special Factory Setting
Address: 0210H
0211H
Operation
Interface:
Keypad/Software
Communication
Related Section: N/A
Default:
0