ASDA-B2
Chapter 7 Servo Parameters
Revision September 2013
7-79
communications.
0
Z
Y
X
COM Port
-
-
RS-485
RS-232
Range
0
0
0 ~ 5
0 ~ 5
Settings:
0: Baud rate 4800 (data transmission speed: bits / second)
1: Baud rate 9600 (data transmission speed: bits / second)
2: Baud rate 19200 (data transmission speed: bits / second)
3: Baud rate 38400 (data transmission speed: bits / second)
4: Baud rate 57600 (data transmission speed: bits / second)
5: Baud rate 115200 (data transmission speed: bits / second)
P3-02
PTL
Communication Protocol
Address: 0304H
0305H
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 8.2
Default:
0x0066
Control
Mode:
ALL
Unit: N/A
Range: 0x0000 ~ 0x0088
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings:
This parameter is used to set the communication protocol. The alphanumeric
characters represent the following: 7 or 8 is the number of data bits; N, E or O refers
to the parity bit, Non, Even or Odd; the 1 or 2 is the numbers of stop bits.
0
Z
Y
X
COM Port
-
-
RS-485
RS-232
Range
0
0
0 ~ 8
0 ~ 8
0: Modbus ASCII mode, <7,N,2>
1: Modbus ASCII mode, <7,E,1>
2: Modbus ASCII mode, <7,O,1>
3: Modbus ASCII mode, <8,N,2>
4: Modbus ASCII mode, <8,E,1>
5: Modbus ASCII mode, <8,O,1>
6: Modbus RTU mode, <8,N,2>
7: Modbus RTU mode, <8,E,1>
8: Modbus RTU mode, <8,O,1>
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.