Chapter 7 Servo Parameters
ASDA-B2
7-100
Revision September 2013
Setting value: 0x05
DO Name
DO Function Description
Trigger
Method
Control
Mode
TPOS
When the drive is in PT mode, TPOS will be activated when
the position error is equal and below the setting value of
P1-54.
Level
Triggered
PT
Setting value: 0x06
DO Name
DO Function Description
Trigger
Method
Control
Mode
TQL
TQL is activated when the drive has detected that the motor
has reached the torques limits set by either the parameters
P1-12 ~ P1-14 of via an external analog voltage.
Level
Triggered
All,
except T,
Tz
Setting value: 0x07
DO Name
DO Function Description
Trigger
Method
Control
Mode
ALRM
ALRM is activated when the drive has detected a fault
condition. (However, when Reverse limit error, Forward limit
error, Emergency stop, Serial communication error, and
Undervoltage these fault occur, WARN is activated first.)
Level
Triggered
All
Setting value: 0x08
DO Name
DO Function Description
Trigger
Method
Control
Mode
BRKR
Electromagnetic brake control. BRKR is activated (Actuation
of motor brake). (Please refer to parameters P1-42 ~ P1-43)
Level
Triggered
All
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.