Chapter 5 Trial Run and Tuning Procedure
ASDA-B2
5-12
Revision September 2013
Tuning Procedure
Display
20. The ratio of Load Inertia to Servo Motor Inertia (J_load /J_motor) cannot be shown in the
display of JOG parameter P4-05 operation. Please press MODE key twice continuously and
the users can see the ratio of Load Inertia to Servo Motor Inertia (J_load /J_motor). Then,
execute JOG operation again, press MODE key once and press SET key twice to view the
display on the keypad. Check if the value of J_load /J_motor is adjusted to a fixed value and
displayed on the keypad after acceleration and deceleration repeatedly.
5.5.1 Tuning Flowchart
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.