ASDA-B2
Chapter 7 Servo Parameters
Revision September 2013
7-95
Setting value: 0x14 ~ 0x15
DI
Name
DI Function Description
Trigger
Method
Control
Mode
SPD0
SPD1
Speed command selection 0 ~ 1 (Command S1 ~ S4)
Command
No.
DI signal of
CN1
Command
Source
Content
Range
SPD1 SPD0
S1 OFF
OFF
Mode
S
External
analog
command
Voltage
between
V-REF and
GND
+/-10 V
Sz
None
Speed
command
is 0
0
S2 OFF
ON
Internal
parameter
P1-09
-60000
~
+60000
r/min
S3 ON
OFF
P1-10
S4 ON
ON
P1-11
Level
Triggered
S
Setting value: 0x16 ~ 0x17
DI
Name
DI Function Description
Trigger
Method
Control
Mode
TCM0
TCM1
Torque command selection 0 ~ 1 (Command T1 ~ T4)
Command
No.
DI signal of
CN1
Command
Source
Content
Range
TCM1 TCM0
T1 OFF
OFF
Mode
T
Analog
command
Voltage
between
V-REF
and GND
+/-10 V
Tz None
Torque
command
is 0
0
T2 OFF
ON
Internal
parameter
P1-12
-300 ~
+300 %
T3 ON
OFF
P1-13
T4 ON
ON
P1-14
Level
Triggered
T
Setting value: 0x18
DI Name
DI Function Description
Trigger
Method
Control
Mode
S-P
Speed / Position mode switching.
OFF: Speed mode, ON: Position mode
Level
Triggered
P, S
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.