ASDA-B2
Chapter 5 Trial Run and Tuning Procedure
Revision September 2013
5-9
5.4 Speed Trial Run without Load
Before speed trial run, fix and secure the motor as possible to avoid the danger
from the reacting force when motor speed changes.
STEP 1:
Set the value of parameter P1-01 to 02 and it is speed (S) control mode. After selecting
the operation mode as speed (S) control mode, please restart the drive as P1-01 is
effective only after the servo drive is restarted (after switching power off and on).
STEP 2:
In speed control mode, the necessary Digital Inputs are listed as follows:
Digital Input
Parameter Setting
Value
Sign
Function Description
CN1 PIN No.
DI1 P2-10=101
SON
Servo
On
DI1-=9
DI2
P2-11=109
TRQLM
Torque limit enabled
DI2-=10
DI3
P2-12=114
SPD0
Speed command selection
DI3-=34
DI4
P2-13=115
SPD1
Speed command selection
DI4-=8
DI5 P2-14=102
ARST
Reset
DI5-=33
DI6
P2-15=0
Disabled
This DI function is disabled
-
DI7
P2-16=0
Disabled
This DI function is disabled
-
DI8
P2-17=0
Disabled
This DI function is disabled
-
DI9
P2-36=0
Disabled
This DI function is disabled
-
By default, DI6 is the function of reverse inhibit limit, DI7 is the function of forward inhibit
limit and DI6 is the function of emergency stop (DI8), if the users do not set the setting
value of parameters P2-15 to P2-17 and P2-36 to 0 (Disabled), the faults (ALE13, 14 and
15) will occur (For the information of fault messages, please refer to Chapter 10).
Therefore, if the users do not need to use these three digit inputs, please set the setting
value of parameters P2-15 to P2-17 and P2-36 to 0 (Disabled) in advance.
All the digital inputs of Delta ASDA-B2 series are user-defined, and the users can set the
DI signals freely. Ensure to refer to the definitions of DI signals before defining them (For
the description of DI signals, please refer to Table 7.A in Chapter 7). If any alarm code
displays after the setting is completed, the users can restart the drive or set DI5 to be
activated to clear the fault. Please refer to section 5.2.
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.