Chapter 7 Servo Parameters
ASDA-B2
7-96
Revision September 2013
Setting value: 0x19
DI Name
DI Function Description
Trigger
Method
Control
Mode
S-T
Speed / Torque mode switching.
OFF: Speed mode, ON: Torque mode
Level
Triggered
S, T
Setting value: 0x20
DI Name
DI Function Description
Trigger
Method
Control
Mode
T-P
Torque / Position mode switching.
OFF: Torque mode, ON: Position mode
Level
Triggered
P, T
Setting value: 0x21
DI Name
DI Function Description
Trigger
Method
Control
Mode
EMGS
Emergency stop. It should be contact “b” and normally ON
or a fault (AL013) will display.
Level
Triggered
All
Setting value: 0x22
DI Name
DI Function Description
Trigger
Method
Control
Mode
NL(CWL)
Reverse inhibit limit. It should be contact “b” and normally
ON or a fault (AL014) will display.
Level
Triggered
All
Setting value: 0x23
DI Name
DI Function Description
Trigger
Method
Control
Mode
PL(CCWL)
Forward inhibit limit. It should be contact “b” and normally
ON or a fault (AL015) will display.
Level
Triggered
All
Setting value: 0x25
DI Name
DI Function Description
Trigger
Method
Control
Mode
TLLM
Torque limit - Reverse operation (Torque limit function is
valid only when P1-02 is enabled)
Level
Triggered
PT, S
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.