Chapter 7 Servo Parameters
ASDA-B2
7-92
Revision September 2013
Settings:
In speed mode, the users can use this parameter to add an offset value to analog
speed input.
P4-23
TAO Analog Torque Input Offset
Address: 042EH
042FH
Operation
Interface:
Keypad / Software
Communication
Related Section: N/A
Default:
0
Control
Mode:
T
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Display
Format:
Decimal
Settings:
In speed mode, the users can use this parameter to add an offset value to analog
speed input.
P4-24
LVL
Undervoltage Error Level
Address: 0430H
0431H
Operation
Interface:
Keypad / Software
Communication
Related Section: N/A
Default:
160
Control
Mode:
ALL
Unit: V (rms)
Range: 140 ~ 190
Data Size: 16-bit
Display
Format:
Decimal
Settings:
When DC Bus voltage is lower than the value of P4-24 x
2
, the fault, Undervoltage
will occur.
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.